iMethod™ Test for Amino Acids Analysis with Cliquid® AA45 Software 2.0
The AB SCIEX iMethod™ Test for Amino Acid Analysis provides a simple to use method and data analysis for the analysis of 45 Amino Acids in physiological fluid using amino reactive isotope coded tags (iTRAQ® Reagents) in conjunction with LC/MS/MS. Included with this test: Cliquid® AA45 Software 2.0
iMethod™ Test for Benzodiazepines Version 1.0 for Cliquid® Software
The AB SCIEX iMethod™ Test for Benzodiazepines allows customers to be up and running quickly with preconfigured settings and report templates specific for the quantification of 30 benzodiazepines and non-benzodiazepine hypnotics (Zaleplone, Zolpidem, Zopidone) in plasma, blood or urine.
Included with this method are: Restek pre-column, 5μm 60 A, PFP Propyl, 10 x 2.1 mm and Restek analytical column, 5μm 60 A, PFP Propyl Column, 50 x 2.1 mm.
iMethod™ Test for Immunosuppressants using On-Line Solid Phase Extraction Version 1.0 for Cliquid® Software
The AB SCIEX iMethod™ Test for Immunosuppressants using On-Line Solid Phase Extraction provides a method for the simultaneous analysis of four immunosuppressants and their internal standards in whole blood using on-line solid phase extraction-high performance liquid chromatography-tandem mass spectrometry.
Included with this test are an Applied Biosystems POROS® R1 20μm Column 30 x 2.1 mm, and a Phenomenex Luna 5 μm Phenyl-Hexyl 50 x 2.1 mm.
iMethod™ Test for Immunosuppressants Version 1.0 for Cliquid® Software
The AB SCIEX iMethod™ Test for Immunosuppressants provides both a direct injection method for the analysis of Cyclosporin A, Everolimus, Sirolimus, and Tacrolimus, together with a method for analysis of Mycophenolic Acid, its glucuronide metabolite (MPAG) and its internal standard (Indomethacin) in plasma. Included with this test are a Phenomenex SecurityGuard Luna C18 cartridge column, 4 x 3.0 mm and SecurityGuard guard cartridge kit.
iMethod™ Test for Low Levels of Testosterone Version 1.0 for Cliquid® Software
The AB SCIEX iMethod™ Test for Low Levels of Testosterone in human serum is for the routine analysis of low levels of Testosterone. Included with this method is a Phenomenex Luna 2.5 μm C18, 100 x 2 mm HPLC column.
iMethod™ Test for Research Into Inborn Errors of Metabolism Version 1.0 for Cliquid® Software
The AB SCIEX iMethod™ Test for Research into Inborn Errors of Metabolism includes both a method for non derivatized samples, and a method for derivatized samples. The test allows customers to simultaneously analyse amino acids and acylcarnitines panels and provides information on over 40 metabolic disorders such as phenylketonuria (PKU) and medium chain acyl-coA dehydrogenase deficiency (MCADD).
iMethod™ Test for Testosterone Version 1.0 for Cliquid® Software
The AB SCIEX iMethod™ Test for Testosterone in human serum is for the routine analysis of Testosterone. Included with this method is a Phenomenex Luna 3.0 μm C18(2), 50 x 2 mm HPLC column and a Fisher Scientific BetaBasic Javelin Guard Column 18 5μm 20 x 2.1 mm.
iMethod™ Test for Vitamin D Version 1.0 for Cliquid® Software
The AB SCIEX iMethod™ Test for Vitamin D allows customers to be up and running quickly with preconfigured settings and report templates specific for commercially available calibrators and controls for MHVD 2 and MHVD 3.
Included with this method is a Phenomenex LUNA C8-2 50X2mm column.